  7 visit www.phoenixcon.com to view our selection of power outlets. 6 the time/current characteristic curve depends on the ambient temperature prevailing. in order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. ambient temperature f -22 -4 14 32 73.4 104 122 140 c -30 -20 -10 0 23 40 50 60 derating factor 0.76 0.79 0.83 0.88 1 1.08 1.16 1.24 thermal-magnetic circuit breaker | tmc 42-01/42-02 single pole thermal-magnetic circuit breaker with tease-free, triple-free, snap action mechanism and two button operation (m-type tmcbe to iec 934). featuring a narrow profile housing, recessed terminals, standard din-rail mounting and precision cbe performance. typical applications circuit protection for process control systems, equpiment manufacturers and instrumentation. approvals authority voltage ratings current ratings vde, demko ac 250 v, dc 65 v 0.10 to 16 a ul 1077, csa ac 250 v, dc 80 v 0.10 to 16 a abs, bv, lros ac 250 v, dc 65 v 0.3 to 16 a label slot zb6 marking system standard current ratings and typical internal resistance values technical data maximum voltage rating ac 250 v, 50/60 hz; dc 80 v current rating range 42-01 : 0.10 ...16 a typical life 5,000 operations at 2xl n temperature range 0 to 55c (+32 to +131f) creepage resistance pti 600 to iec 112 insulation co-ordination (iec 664 and 664a) rated impulse withstand voltage pollution degree operating area 4k v 3 dielectric strength (iec 664 and 664a) test voltage operating area ac 4,000 v (double insulation) insulation resistance interrupting capacity >100 m ? (dc 500 v) (vde 0660, part 101, p-2) 0.05 to 0.8 a self limiting 1 to 2 a 200 a 2.5 to 16 a 400 a interrupting capacity (ul 1077/en60934 pc1) i n u n self limiting 0.05 to 4.5 a 250 v ac 200 a 0.05 to 16 a 250 v ac 1,000 a 0.05 to 16 a 80 v dc 1,000 a environmental protection (iec 529/din 40050) operating area ip 40,terminal area ip 20 vibration 5g (57-50 hz), +0.38 mm (10-57 hz) to iec 68-2-6, test fc 10 frequency cycles/axis shock 25g (11ms) to iec 68-2-27,test ea corrosion 96 hours at 5% saltspray to iec 68-2-11,test ka humidity 240 hours at 95% rh to iec 68-2-3,test ca weight approx. 60g conductor size 0.5-6mm 2 (awg 20-awg 10) recommended torque 0.8 nm max c-rail adapter 5650505 thermal-magnetic circuit breakers tmc 42-01 single pole tmc 42-02 double pole ohms current rating type part# type part # 131.00 0.10 tmc42-01-0.1 a 5530915* tmc42-02-0.1 a 5650123* 40.00 0.20 tmc42-01-0.2 a 5650102 tmc42-02-0.2 a 5650124* 19.30 0.30 tmc42-01-0.3 a 5650103* tmc42-02-0.3 a 5650127* 10.40 0.40 tmc42-01-0.4 a 5530944* tmc42-02-0.4 a 5531244* 7.10 0.50 tmc42-01-0.5 a 5650106 tmc42-02-0.5 a 5531257* 4.30 0.60 tmc42-01-0.6 a 5530960* tmc42-02-0.6 a 5531260* 2.50 0.80 tmc42-01-0.8 a 5530986* tmc42-02-0.8 a 5531286* 1.67 1.00 tmc42-01-1.0 a 5650108 tmc42-02-1.0 a 5531299 1.22 1.22 tmc42-01-1.2 a 5531008* tmc42-02-1.2 a 5531309* 0.61 1.50 tmc42-01-1.5 a 5650109 tmc42-02-1.5 a 5650129* 0.55 1.80 tmc42-01-1.8 a 5650110* tmc42-02-1.8 a 5531325* 0.38 2.00 tmc42-01-2.0 a 5600314 tmc42-02-2.0 a 5531388 0.24 2.50 tmc42-01-2.5 a 5650113* tmc42-02-2.5 a 5650130* 0.19 3.00 tmc42-01-3.0 a 5650114 tmc42-02-3.0 a 5650131 0.16 3.50 tmc42-01-3.5 a 5531053* tmc42-02-3.5 a 5531367* 0.09 4.00 tmc42-01-4.0 a 5531066 tmc42-02-4.0 a 5650134* 0.09 4.50 tmc42-01-4.5 a 5650115* tmc42-02-4.5 a 5650135* 0.06 5.00 tmc42-01-5.0 a 5531082 tmc42-02-5.0 a 5651396 0.07 5.50 tmc42-01-5.5 a 5531095* tmc42-02-5.5 a 5531406* 0.04 6.00 tmc42-01-6.0 a 5531105 tmc42-02-6.0 a 5650136* 0.04 6.50 tmc42-01-6.5 a 5650116* tmc42-02-6.5 a 5650137* 0.03 7.00 tmc42-01-7.0 a 5650117* tmc42-02-7.0 a 5531435* 0.02 8.00 tmc42-01-8.0 a 5650120 tmc42-02-8.0 a 5650138* 0.02 9.00 tmc42-01-9.0 a 5531147* tmc42-02-9.0 a 5531451* <0.02 10.00 tmc42-01-10 a 5650121 tmc42-02-10 a 5531464 <0.02 11.00 tmc42-01-11 a 5531163* tmc42-02-11 a 5531477* <0.02 12.00 tmc42-01-12 a 5650122* tmc42-02-12 a 5650141* <0.02 13.00 tmc42-01-13 a 5531189* tmc42-02-13 a 5531493* <0.02 14.00 tmc42-01-14 a 5531192* tmc42-02-14 a 5531503* <0.02 15.00 tmc42-01-15 a 5600310 tmc42-02-15 a 5600309 <0.02 16.00 tmc42-01-16 a 5531202 tmc42-02-16 a 5650142* * indicates breakers that are made-to-order and may require an 8 week lead time. dimensions single pole double pole   
                 !" ! #! ! $% &' #"# ( )   


     *!"! + ,    -
   internal wiring diagram                  
     +"%# . /*! +" +"% "! !#  
 0/ 10/ 10/                  
     +"%# . /*! +" +"% "! !#    0/ 10/ 10/ typical time/current characteristics at 23c direct current ? magnetic tripping currents are increased by 30% in dc circuits with the effect of shifting the magnetic trip range 30% to the right of ac trip curves.  ( ) ( )    internal wiring diagram


▲Up To Search▲   

 
Price & Availability of 5531066

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X